LK Automation Limited LK Automation Limited
Information sort OMRON
Home >> Supply
SRT2-ID08 OMRON Transistor Remote I/O Terminals OMRON SRT2-ID08

Control power supply voltage: 125 VDC.
Input: DC, Input voltage range, 0.2 to 12 V.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL) SRT2-ID08.
Detect three-phase AC current for uunder and/or overcur,
rent using current converter.
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T) SRT2-ID08.
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verse current detection.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F) SRT2-ID08.
LED operation indicator.
UL/CSA approval (SDV-F@). Category: incidental cover type.
Structure: DIN guide rail mounting type.
Capacity: 50W.
Output voltage: 12V.
Output current: 4.3A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device OMRON SRT2-ID08.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products OMRON SRT2-ID08.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock OMRON SRT2-ID08.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
"

I/O classification: Input.
Internal I/O circuit common: NPN (+ common).
I/O points: 8.
Rated voltage: 24 VDC.
I/O rated voltage: 24 VDC.
Long-distance Communications Supported by SRT2 Models,
(Long-distance/High-speed Communications Selection).
Ultra-compact at 80 x 48 x 50 (W x H x D) mm for,
4-point and 8-point terminals aand 105 x 48 x 50,
(W x H x D) mm for 16-point terminals SRT2-ID08.
Two independent power supplies can be used,
because the I/O terminals are insulated from the internal circuits.
DIN track mounting and screw mounting are both supported.
Related supply information