LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
S8JX-P15005C EtherNet/IP Connection Guide ()
Product model: S8JX-P15005C
Name: Digital Controller
Brand: OMRON
Sort: EtherNet/IP Connection Guide
File language: English
Power ratings: 240 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC)*1.
Output voltage: 24 V.
Output current: 10 A.
Alarm output *2: Sinking.
UL Class 2 Output standards: --.
Model number(screw terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication S8JX-P15005C EtherNet/IP Connection Guide.
Monitor and Simple Functions for.
Easy System Commissioning S8JX-P15005C
New 90-W models with indication monitor that.
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1) S8JX-P15005C EtherNet/IP Connection Guide.
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.) Conduit: JIS B 0202 G½.
Applicable cable: Cabtire cable (anticorrosive).
Inner diameter (D)of seal rubber: 14 mm.
External diameter of cable: Min, 12 mm; Max, 14 mm.
Applicable model: WL-N, WL, D4A-@N, D4B-@N, ZE, ZV, ZV2, XE, XV, XV2.
Connectors (SC Series) S8JX-P15005C EtherNet/IP Connection Guide.
Cabtire cables and flexible tubes with various diameters are used to,
connect machine tools and controllers with Limit Switches. To ensure,
the watertightness of the edges of the conduits, use an SC Connector,
that is suitable for the external diameter of cable and model of Limit Switch. Control power supply voltage: 125 VDC.
Input: DC or AC (selectable), Input voltage range, 10 to 300 V.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL).
Detect three-phase AC current for under and/or overcur,
rent using current converter.
Availlable in 7 supply voltage configurations S8JX-P15005C Manual.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verrse current detection S8JX-P15005C Manual.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@).
Related products
OMRON
Switching Mode Power Supply
S8VM-15005CD
OMRON Switching Mode Power Supply S8VM-15005CD
Category: incidental cover type. Structu
OMRON
Switching Mode Power Supply
S8VM-15005C
OMRON Switching Mode Power Supply S8VM-15005C
Category: incidental cover type. Structu
OMRON
Switching Mode Power Supply
S8JC-ZS15005CD-AC2
OMRON Switching Mode Power Supply S8JC-ZS15005CD-AC2
Type: S8JC-ZS series models list. Meet t
OMRON
Switching Mode Power Supply
S8JC-Z15005C
OMRON Switching Mode Power Supply S8JC-Z15005C
Type: S8JC-Z series models list. Meet th