LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
S8JX-P10048CD Connection Guide ()
Product model: S8JX-P10048CD
Name: Digital Controller
Brand: OMRON
Sort: Connection Guide
File language: English
Power ratings: 240 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC)*1.
Output voltage: 24 V.
Output current: 10 A.
Alarm output *2: Sinking.
UL Class 2 Output standards: --.
Model number(screw terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication S8JX-P10048CD Connection Guide.
Monitor and Simple Functions for.
Easy System Commissioning S8JX-P10048CD
New 90-W models with indication monitor that.
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1) S8JX-P10048CD Connection Guide.
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.) Type: S8JC-ZS series models list.
Meet the criteria: CE (EN50178).
Configuration: power supply with cover; bottom surface mounting.
Input voltage: 200 ~ 240VAC.
Rated power: 15W.
Output voltage: 12VDC.
Output current: 1.3A.
Economic type power supply S8JC-Z additional models,
The new power S8JC-ZS has a CE certification mark to market S8JX-P10048CD Connection Guide.
Product features: reduce material costs;
Export machinery to be used to meet specific safety standards;
Through the DIN guide rail installation, significant savings in time. Control power supply voltage: 100/110 VDC.
Input: DC or AC (selectable), Input voltage range, 0.2 to 12 V.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL).
Detect three-phase AC current for under and/or overcur,
rent using current converter.
Availaable in 7 supply voltage configurations S8JX-P10048CD Manual.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verrse current detection S8JX-P10048CD Manual.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@).
Related products
OMRON
Switching Mode Power Supply
S8JC-Z10048CD
OMRON Switching Mode Power Supply S8JC-Z10048CD
Type: S8JC-Z series models list. Meet th
OMRON
Switch Mode Power Supply
S8JX-G10048CD
OMRON Switch Mode Power Supply S8JX-G10048CD
Configuration: Covered Power Supplies.
OMRON
Switch Mode Power Supply
S8JX-G30048CD
OMRON Switch Mode Power Supply S8JX-G30048CD
Configuration: Covered Power Supplies.