K3HB-VLC-BT11 User's Manual ()
Product model: K3HB-VLC-BT11
Name: Digital Temperature Controllers
Brand: OMRON
Sort: User's Manual
File language: English
Setting range: 0.1 to 1 A AC/DC, 0.5 to 5 A AC/DC.
Power supply voltage: 100 to 240 VAC.
Ideal for Current Monitoring for.
Industrial Facilities and Equipment.
Monitor for overcurrents and undercurrents simultaneously.
Separate settings and outputs supported for overcurrents and undercurrents.
Use commercially available CTs (CT current on secondary,
side: 0 to 1 A or 0 to 5 A) K3HB-VLC-BT11 User's Manual K3HB-VLC-BT11
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
Two sets of SPDT output contacts, 5 A at 250 VAC (resistive load).
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply. Input type: DC current input K3HB-VLC-BT11 User's Manual.
Output type: linear; voltage; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table K3HB-VLC-BT11 User's Manual.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DeviceNeRated input voltage: 3-phase 3-wire mode, 200, 220, 230, or 240 VAC.
Ideal for 3-phase Voltage Asymmetry.
Monitoring for Industrial Facilities and Equipment.
Greater resistance to inverter noise.
Monitor voltage asymmetry, phase sequence, and phase loss in three,
phase three-wire circuits with one unit.
One SPDT output relay, 5 A at 250 VAC (resistive load).
World-wide power specifications supported by one unit.
(Set with a rotary switch.).
Relay status can be monitored using LED indicator. Control supply voltage: 200 VAC; With voltage fluctuation compensation.
Operating current: 32 to 80 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles out the burnned element even if one heater el,
ement among several heater elements has been burned out K3HB-VLC-BT11 Manual.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with booth single-phase and three-phase heaters K3HB-VLC-BT11 Manual.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage.
Related products
OMRON
Load sensor, mV instrument
K3HB-VLC-CPEC11 AC/DC24
OMRON Load sensor, mV instrument K3HB-VLC-CPEC11 AC/DC24
Category: external supply 100mA DC5V typ
OMRON
Load sensor, mV instrument
K3HB-VLC-CPEC21 AC/DC24
OMRON Load sensor, mV instrument K3HB-VLC-CPEC21 AC/DC24
Category: external supply 100mA DC5V typ