K3HB-VLC-E-DRT1 AC100-240 PDF datasheet (datasheet)
Product model: K3HB-VLC-E-DRT1 AC100-240
Name: Load sensor, mV instrument
Brand: OMRON
Sort: PDF datasheet
File language: English
Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET, COMPENSATION) is equipped with.
External power supply DC12V80mA.
DeviceNet; DeviceNet:--.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
High speed pulse.
Measuring, increasing or decreasing pulse meter K3HB-VLC-E-DRT1 AC100-240 PDF datasheet.
Action determine the color, can switch the green / Red 2 kinds of color display K3HB-VLC-E-DRT1 AC100-240
The best choice of rotating encoder and all kinds of ON/OFF pulse signal at high speed,
Cumulative pulse input is 50kHz, phase difference pulse is 25kHz, increase or decrease of pulse is 30kHz.
Support for no voltage contact input can be up to 3Input type: DC voltage input type.
Output type: communication; RS-485; NPN open collector (HH, H, PASS, L, LL) K3HB-VLC-E-DRT1 AC100-240 PDF datasheet.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table.
Action determine the color, can switch the green / Red 2 kinds of color display K3HB-VLC-E-DRT1 AC100-240 PDF datasheet.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DeviceNTime specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start off operation K3HB-VLC-E-DRT1 AC100-240 PDF catalog.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-VLC-E-DRT1 AC100-240 PDF catalog. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
Related products
OMRON
Temperature panel
K3HB-HTA-DRT1 AC100-240
OMRON Temperature panel K3HB-HTA-DRT1 AC100-240
Type of input: platinum resistance / the
OMRON
Load sensor, mV instrument
K3HB-VLC-E-DRT1 AC/DC24
OMRON Load sensor, mV instrument K3HB-VLC-E-DRT1 AC/DC24
Category: external supply 100mA DC5V typ