Type of input: platinum resistance / thermocouple input.
Event input terminal 4 points (TIMING, S-TIM, HOLD, RESET) is equipped with.
Linear: current; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
Temperature indicator and measurement of various processes K3HB-HTA-FLK1AT11 Communications Manual.
Action determine the color, can switch the green / Red 2 kinds of color display
K3HB-HTA-FLK1AT11
High speed sampling of 50 /s (20ms).
0.01 degree: platinum temperature resistance body Pt100 high resolution.
Thermocouple sensor (full range) to support the resolution of 0.1.
The temperature input compensation can be easily set by 2 points.
DeLinear Sensor Indicator for High-speed, High,
precision Measurement and Discrimination K3HB-HTA-FLK1AT11 Communications Manual.
Easy recognition of judgement results using color display that can be,
switched between red and green.
Equipped with a position meter that represents measured amounts and,
relative positions.
Develop a variety of measurement and discrimination applications us,
ing external event inputs.
Series expanded to include DeviceNet models.
Short body with depth of only 95 mm (from behind the front panel),
or 97 mm for DeviceNet models K3HB-HTA-FLK1AT11 Communications Manual.
UL certification approval (Certification Mark License).
CE Marking conformance by third party assessment body.
Water-resistant enclosure conforms to NEMA 4X (equivalent to IP66). Rated input voltage: 3-phase 3-wire mode, 380, 400, 415, or 480 VAC.
Ideal for Monitoring 3-phase Power Supplies.
for Industrial Facilities and Equipment.
Greater resistance to inverter noise.
Monitor undervoltages, phase sequence, and phase loss in three,
phase three-wire circuits with one unit.
One SPDT output relay, 5 A at 250 VAC (resistive load).
World-wide power specifications supported by one unit.
(Set with a rotary switch.).
Relay status can be monitored using LED indicator. Time specification: Instantaneous type.
Current setting range: 50 to 160 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation K3HB-HTA-FLK1AT11 Manual.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequeency, basic,
frequency, and load conditions K3HB-HTA-FLK1AT11 Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,