LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
K3HB-SSD-FLK1AT11 Communications Manual ()
Product model: K3HB-SSD-FLK1AT11
Name: Digital Temperature Controllers
Brand: OMRON
Sort: Communications Manual
File language: English
Control supply voltage: 100/ 200 VAC; Without voltage fluctuation compensation.
Operating current: 1 to 2 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal K3HB-SSD-FLK1AT11 Communications Manual.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out K3HB-SSD-FLK1AT11
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage K3HB-SSD-FLK1AT11 Communications Manual. Input type: DC current input.
Output type: no output.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) some models are not equipped with depth.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table K3HB-SSD-FLK1AT11 Communications Manual.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
Series of DeviceNet type.
The depth (panel below) is only short size 95mm. Type of input: platinum resistance / thermocouple input.
Event input terminal 4 points (TIMING, S-TIM, HOLD, RESET) is equipped with.
Relay contact: HH; PASS1c, H, L, LL: each 1a.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
Temperature indicator and measurement of various processes K3HB-SSD-FLK1AT11 Manual.
Action determine the color, can switch the green / Red 2 kinds of color display.
High speed sampling of 50 /s (20ms).
0.01 degree: platinum temperature resistance body Pt100 high ressolution K3HB-SSD-FLK1AT11 Manual.
Thermocouple sensor (full range) to support the resolution of 0.1.
The temperature input compensation can be easily set by 2 points.
Device
Related products