Product model: K2CM-4M
Name: Digital Temperature Controllers
Brand: OMRON
Sort: Communications Manual
File language: English
Category: external supply 100mA DC10V.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
Relay contact: H; PASS1c, L: each 1c.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified K2CM-4M Communications Manual K2CM-4M
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identificationInput type: NPN/ voltage pulse input type K2CM-4M Communications Manual.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Transistor: -; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table K2CM-4M Communications Manual.
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of wide range of pulse interval time.
Measuring, calculating and displaying the pulse interval between 2 points.
Pulse interval measurement range, maximumPower supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 2.00 to 22.00 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control,, phase control, and cyclic control K2CM-4M Manual.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreent relay or for motor or lamp loads K2CM-4M Manual.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).
Related products
OMRON
Safety Laser Scanner
OS32C-SP1-4M
OMRON Safety Laser Scanner OS32C-SP1-4M
Description: OS32C with side location ca
OMRON
Heater Element Burnout Detector
K2CU-P2A-A
OMRON Heater Element Burnout Detector K2CU-P2A-A
Control supply voltage: 100/ 200 VAC Wi
OMRON
Heater Element Burnout Detector
K2CU-F40A-DGS
OMRON Heater Element Burnout Detector K2CU-F40A-DGS
Control supply voltage: 110 VAC With vo
OMRON
Motor Protective Relay
K2CM-Q1LSA
OMRON Motor Protective Relay K2CM-Q1LSA
Time specification: Instantaneous type.