K2CU-P4A-A PDF datasheet (datasheet)
Product model: K2CU-P4A-A
Name: Heater Element Burnout Detector
Brand: OMRON
Sort: PDF datasheet
File language: English
Rated input: 3-phase 3-wire mode, 3-phase 4-wire mode;
380, 400, 415, 480 VAC, 220, 230, 240, 277 VAC.
Ideal for Monitoring 3-phase Power.
Supplies for Industrial Facilities and Equipment.
Greater resistance to inverter noise.
Monitor overvoltages, undervoltages, phase sequence,
and phase loss for three-phase 3-wire or 4-wire power,
supplies with just one Unit K2CU-P4A-A PDF datasheet.
Switch setting for 3-phase 3-wire or 3-phase 4-wire power supply K2CU-P4A-A
Two SPDT output relays, 5 A at 250 VAC (resistive load).
Output overvoltages and undervoltages using separate relays.
World-wide power specifications supported by one Unit (switchable).
Output status can be monitored using LED indicator. Category: external supply 100mA DC10V K2CU-P4A-A PDF datasheet.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
DeviceNet; DeviceNet:--.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified K2CU-P4A-A PDF datasheet.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identificationTime specification: Instantaneous type.
Current setting range: 8 to 26 A.
Operating voltage: 400/440 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated frrom the start of operation K2CU-P4A-A PDF catalog.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K2CU-P4A-A PDF catalog. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
Related products
OMRON
Heater Element Burnout Detector
K2CU-P1A-B
OMRON Heater Element Burnout Detector K2CU-P1A-B
Control supply voltage: 110/220 VAC Wit
OMRON
Heater Element Burnout Detector
K2CU-F10A-EGS
OMRON Heater Element Burnout Detector K2CU-F10A-EGS
Control supply voltage: 200 VAC With vo
OMRON
Heater Element Burnout Detector
K2CU-F40A-EGS
OMRON Heater Element Burnout Detector K2CU-F40A-EGS
Control supply voltage: 200 VAC With vo
OMRON
Heater Element Burnout Detector
K2CU-F40A-FGS
OMRON Heater Element Burnout Detector K2CU-F40A-FGS
Control supply voltage: 220 VAC With vo