Product: 60° Flexible Shower Nozzle Cap.
Wide Range of Nozzles for Optimal.
Ionization.
A wide range of nozzle variations.
High-frequency AC method with excellent ion balance. Input type: high speed response type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with K2CM-2LSA Communications Manual.
External power supply DC12V80mA.
Output type: transistor; - NPN open collector (HH, H, PASS, L, LL)
K2CM-2LSA
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
High speed, high precision measurement, determine the color display,
Can switch the green / Red 2 kinds of display colors.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations K2CM-2LSA Communications Manual.
Series of DeviceNet type.
The depth (panel below) is only short size 95mm.
Setting range: 2 to 20 mA AC/DC, 10 to 100 mA AC/DC, 50 to 500 mA AC/DC.
Power supply voltage: 24 VAC/DC.
Ideal for Current Monitoring for.
Industrial Facilities and Equipment.
Monitor for overcurrents and undercurrents simultaneously.
Separate settings and outputs supported for overcurrents and undercurrents K2CM-2LSA Communications Manual.
Use commercially available CTs (CT current on secondary,
side: 0 to 1 A or 0 to 5 A).
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
Two sets of SPDT output contacts, 5 A at 250 VAC (resistive load).
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply. Time specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicaated from the start of operation K2CM-2LSA Manual.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K2CM-2LSA Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.