Product model: K2CM-Q4MA
Name: Digital Temperature Controllers
Brand: OMRON
Sort: Communications Manual
File language: English
Measuring current: 10 to 100 A AC, 20 to 200 A (See note.).
Supply voltage: 100-115 VAC.
Ideal for current monitoring for,
industrial facilities and equipment.
Monitor for overcurrents or undercurrents.
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately K2CM-Q4MA Communications Manual.
One SPDT output relay, 6 A at 250 VAC (resistive load) K2CM-Q4MA
Output relay can be switched between normally open and,
normally closed.
Process control signal (4 to 20 mA) and commercial CT input,
(0 to 1 A or 0 to 5 A) supported.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply. Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control K2CM-Q4MA Communications Manual.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 2.00 to 22.00 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload K2CM-Q4MA Communications Manual.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 0.200 to 2.200 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, pphase control, and cyclic control K2CM-Q4MA Manual.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreent relay or for motor or lamp loads K2CM-Q4MA Manual.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).
Related products
OMRON
Motor Protective Relay
K2CM-Q2LAV
OMRON Motor Protective Relay K2CM-Q2LAV
Time specification: Instantaneous type.
OMRON
Motor Protective Relay
KK2CM-1LA
OMRON Motor Protective Relay KK2CM-1LA
Time specification: Inverse type. Curren
OMRON
Motor Protective Relay
K2CM-Q4MA
OMRON Motor Protective Relay K2CM-Q4MA
Time specification: Instantaneous type.
OMRON
Motor Protective Relay
K2CM-Q2LSA
OMRON Motor Protective Relay K2CM-Q2LSA
Time specification: Instantaneous type.