GRT1-END-M OPERATION MANUAL ()
Product model: GRT1-END-M
Name: CompoBus/S Module
Brand: OMRON
Sort: OPERATION MANUAL
File language: English
Input capacity: 16 points.
Mounted relays: NY-5W-K-IE (Fujitsu Component).
Rated load: Resistance load,
250 VAC 2 A/output, common 8 A,
30 VDC 2 A/output, common 8 A.
Rated ON current: 3 A/output.
Maximum contact voltage: 250 VAC, 125 VDC.
Maximum contact current: 3 A/output.
Maximum switching capacity: 750 VAAC, 90 WDC GRT1-END-M OPERATION MANUAL.
Minimum applicable load(reference value): 5 VDC 1mA GRT1-END-M
Mechanical service life: 20,000,000 operations min.
Electrical service life: 100,000 operations min.
Number of circuits per common: 8 points/common.
Output indicators: LED display (yellow).
Isolation method: Relay isolation.
I/O power supply method: The relay drive power,
is supplied from the unit power supply GRT1-END-M OPERATION MANUAL.
Unit power supply current consumption:
210 mA max. (for 20.4 to 26.4-VDC power supply voltage).
Weight: 290 g max.
Expansion functions: Enabled.
Output handling for communica tions errors:
Select either hold or clear.
Short-circuit protection function: No.
High-speed digital I/O terminal with the,
screw type terminal block for EtherCAT,
communications.
Detachable screw terminal block facilitates,
the maintenance GRT1-END-M OPERATION MANUAL.
The expansion unit can be connected.
(One expansion unit per one I/O terminal unit.)
Input/output point can be flexibly increased,
depending on the system.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary switch and with tool software.
When setting the nodes with rotary switch,
setting is easy and node identification becomes,
possible for maintenance. Number of phases: Single-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: No.
Applicable load: 45 A, 200 to 480 VAC .
Compact, Sllim-profile SSRs with Heat,
Sinks GRT1-END-M Manual. Models with No Zero Cross for,
a Wide Range of Applications.
RoHS compliant.
Models also available with no zero cross,
Surge pass protection improved surge dielectric strength for,
output cuurrents GRT1-END-M Manual. (OMRON testing).
Compact with a slim profile.
Mount to DIN Track or with screws.
Conforms to UL, CSA, and EN standards (TÜV certification).
Related products
OMRON
System Units
GRT1-PC8
OMRON System Units GRT1-PC8
Name: System Units I/O Power Feed Unit.
OMRON
CompoNet Communications Unit
GRT1-OD8-1
OMRON CompoNet Communications Unit GRT1-OD8-1
Name: Slice I/O Units Digital I/O Units
OMRON
System Units
GRT1-END
OMRON System Units GRT1-END
Name: System Units End Unit 2. Speci
OMRON
CompoNet Communications Unit
GRT1-DA2C
OMRON CompoNet Communications Unit GRT1-DA2C
Name: Slice I/O Units Analog I/O Units.