Model: CPM2C-24EDTM. Units with 24 I/O points
2 MIL connectors.
Inputs: 16 inputs.
Outputs: 8 outputs.
Input type: 24 VDC.
Output type: sinking transistor.Model : CV1000-DM151.
Available CV1000/2000/CVM1-CPU21-V2.
128k words.I/O bits: 5, 120 (Expan-sion Racks: 7).
Program capacity: 60K steps.
Data memory capacity: 128K words (DM: 32K words, EM: 32K words ×3 banks)Commonly used with other Communications Units CS1W-SPU01-V2 INSTRUCTION MANUAL
CS1W-SPU01-V2 Unit classification: CJ1 Special I/O Units.
name: Position control unit.
Specifications; Control method/Control,
output interface:Open-loop control by pulse,
train output/Open-collector output;
Number of control axes : 2 axes.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0 CS1W-SPU01-V2 INSTRUCTION MANUAL. 25A; 24V, --.
Standards: UC1, CE.
High-speed, High-precision positioning,
with 1, 2, or 4 axes.
Versatile functions and superb performance,
enable the construction of compact,
high-performance machines.
With its ultra-compact size of 31 × 90mm (W×H),
this highly space-efficient Position Control Unit,
(PCU) enables up to 4 axes of motor control.
Power supply: AC power supply CS1W-SPU01-V2 INSTRUCTION MANUAL.
Output method: Transistor output source type.
Inputs points: 6 points.
Outputs points: 4 points.Emergency stop unit: 2 inputs/2 outputs, 4 general-purpose inputs.Product name: CS1 Expansion Backplanes.
Specifications: For CS-series,
Unit only Note: C200H series,
Units cannot be mounted; 5 slots.
Mountable configuration units:
Basic I/O Units, CS-series Basic I/O Unit,
Yes; C200H series Basic I/O Unit, No;
C200H Group-2 High density I/O Unit, No.
Special I/O Units: CS-series Special I/O Unit,
Yes; C200H series Special I/O Unit, No.
CPU Bus Units: CS-series CPU Bus Unit, Yes.
Current consumption: 5V system, 0.23A;
26 V system, --.
Standards: U, C, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control. Model : C500-LK009-V1.
Maximum of 32 PCs can be linked.Unit type: CJ1 Basic I/O Units.
Product name: Interrupt Input Unit.
Specifications: I/O points, 16 inputs;
Input voltage current, 24 VDC, 7mA;
Commons: 16 points, 1 common;
Input pulse widt conditions, ON time:
0.05 ms max. OFF time: 0.5 ms max;
Max. Units mountable per Unit, 2;
External connection, Removable terminal block.
No. of words allocated: 1 word.
Current consumpttion: 5V, 0 CS1W-SPU01-V2 Manual. 08A; 24V, --.
Standards: UC1, N, L, CE.
High-speed Starting of I/O InterruptTasks.
Use Up to Two Units for a Total of Up,
to 32 Interrupt Inputs.
Receive inputs to start I/O interrupt tasks.
When the Interruptt Input Unit receives an input,
the CPU Unit will interrupt execution of the,
cyclic tasks in the normal CS1W-SPU01-V2 Manual.
program and execute an I/O interrupt task.