Model: CPM2C-20C1DT1C-D. CPU Unit: Units with 20 I/O points.
2 Fujitsu connectors.
Inputs: 12 inputs.
Outputs: 8 outputs.
Input type: 24 VDC.
Output type: sourcing transistor.
Internal clock: Yes.Name: Three-tier Screw Terminal Block.
Specifications: Inputs/Outputs;
8 inputs/8 outputs; PNP;
Without Short-circuit and,
Disconnected Line Detection CJ1W-TC101 PROGRAMMING MANUAL.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet
CJ1W-TC101
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site CJ1W-TC101 PROGRAMMING MANUAL.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Model : CVM1D-BC051.
5-slot.Model: C200H-B7AO1.
I/O points: 16 output points.
Weight: 200g max.CV500-RM SYSMAC BUS Remote I/O Master Unit Wired CV500-RM221.
Wire Type.Name: Host Link Module.
Model: C200H-LK201-V1.
Communication ports: 1 RS-232C, 25 pin female CJ1W-TC101 PROGRAMMING MANUAL. I/O Interface UnitUnit type: CS1 Special I/O Units.
Product name: Isolated-type DC Input Unit.
Input points : 4 inputs.
Signal range: 4 to 20 mA, 0 to 20 mA,
0 to 10 V, ±10 V, 0 to 5 V, ±5 V,
1 to 5 V, 0 to 1.25 V, ±1.25 V.
Conversion speed (resolution):
20 ms/4 inputs, 10 ms/2 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.12A.
Standards: UC1, N, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and sppace compared,
with previous systems CJ1W-TC101 Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CJ1W-TC101 Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.