3G3AX-MX2-ECT Communications Manual ()
Product model: 3G3AX-MX2-ECT
Name: Digital Temperature Controllers
Brand: OMRON
Sort: Communications Manual
File language: English
Function name: single phase 200V.
Power: 0.1KW.
Rated output voltage: 3 phase, 200 ~ 240V (the output voltage can not exceed the input voltage).
Built in brake unit (brake resistance needs to be matched).
Weight: 1.0KG.
Dimension (w * h) 128mm *:68.
Outline dimension (deep):109mm.
Mechanical automation concept 3G3AX-MX2-ECT Communications Manual.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication 3G3AX-MX2-ECT
Driver programming function.
Current vector control.
High starting torque: 0.5Hz up to 200%.
Safety features, in compliance with ISO13849-1:2008 EN (Cat.3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H. To achieve a more rapid, more advanced rotation control, positioning more accurate,
Improve productivity, high speed, high precision to double productivity 3G3AX-MX2-ECT Communications Manual.
3F88L-162, 32 point output.
Compact design to save space.
The cam output can be adjusted according to the rotation angle by the simple operation and the setting.
Through the UL/CSA standard certification, in accordance with the EC directive, can guarantee the internationalization of the application 3G3AX-MX2-ECT Communications Manual.
With a variety of convenient field functions. Function name: 3 phase 200V.
Power: 3.7KW.
Rated output voltage: 3 phase, 200 ~ 240V (the output voltage can not exceed the input voltage).
Built in brake unit (brake resistance needs to be matched).
Weight: 2.0KG.
Dimension (w * h) 128mm *:140.
Outline dimension (deep):170.5mm.
Mechanical automation concept.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication.
Driver programming function.
Current vector control.
High starting torque: 0.5Hz up to 200%.
Safety features, in compliance with ISO138499-1:2008 EN (Cat 3G3AX-MX2-ECT Manual. 3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H. When the power supply capacity exceeds the power supply capacity of the inverter or the need to improve the power factor, it is required to connect the AC reactor 3G3AX-MX2-ECT Manual.
Please according to the maximum capacity of heavy load and light load rated conditions suitable for motor to select option.
Related products
OMRON
AC reactor
3G3AX-AL2110
OMRON AC reactor 3G3AX-AL2110
When the power supply capacity exceeds t
OMRON
DC reactor
3G3AX-DL2004
OMRON DC reactor 3G3AX-DL2004
Inverter input power: 3 phase / single p
OMRON
DC reactor
3G3AX-DL2110
OMRON DC reactor 3G3AX-DL2110
Inverter input power: 3 phase / single p
OMRON
DC reactor
3G3AX-DL2150
OMRON DC reactor 3G3AX-DL2150
Inverter input power: 3 phase / single p