3G3AX-DI01-Z Communications Manual ()
Product model: 3G3AX-DI01-Z
Name: Digital Temperature Controllers
Brand: OMRON
Sort: Communications Manual
File language: English
Inverter input power: 3 phase / single phase AC200V.
Weight: 6.5KG.
Standard applicable line diameter: 22 square mm or more.
Used to suppress harmonic currents generated by a transducer.
The effect of harmonic current suppression is better than that of AC reactor,
And it can be used with AC reactor. Specification: three phase 400V 3G3AX-DI01-Z Communications Manual.
Power: 55KW.
Maximum output voltage: three phase AC380 ~ 480V (input voltage correspondence) 3G3AX-DI01-Z
Rated voltage: three phase 480V ~ 50/60Hz AC380.
Weight: about 36kg.
In the inverter is equipped with the servo can play the same static torque with PG vector control function,
DeviceNet communication makes the application field more extensive.
The high functional specifications are concentrated in the compact 3G3AX-DI01-Z Communications Manual.
Equipped with PG vector control.
Subsequent models of 3G3RV.
CV/VT selection function.
Rich online automatic adjustment function (self learning function).
CX-Drive software.
DeviceNet correspondence correspondence.
Multi function input and output function.
Colorful function.
Brake transistor built-in.
Protection function. Function name: single phase 200V 3G3AX-DI01-Z Communications Manual.
Power: 0.2KW.
Rated output voltage: 3 phase, 200 ~ 240V (the output voltage can not exceed the input voltage).
Built in brake unit (brake resistance needs to be matched).
Weight: 1.0KG.
Dimension (w * h) 128mm *:68.
Outline dimension (deep):109mm.
Mechanical automation concept.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication.
Driver programming function.
Current vector control.
High starting torque: 0.5Hz up to 200%.
Safety features, in compliance with ISO138449-1:2008 EN (Cat 3G3AX-DI01-Z Manual. 3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H. When the power supply capacity exceeds the power supply capacity of the inverter or the need to improve the power factor, it is required to connect the AC reactor 3G3AX-DI01-Z Manual.
Please according to the maximum capacity of heavy load and light load rated conditions suitable for motor to select option.
Related products
OMRON
Output noise filter
3G3AX-NFO04
OMRON Output noise filter 3G3AX-NFO04
Power supply: 3 phase 3 line rated volta
OMRON
AC reactor
3G3AX-AL2055
OMRON AC reactor 3G3AX-AL2055
When the power supply capacity exceeds t
OMRON
Input noise filter
3G3AX-NFI43
OMRON Input noise filter 3G3AX-NFI43
Box protection class: plastic, IP00. Ter
OMRON
Brake resistance
3G3AX-RBC4001
OMRON Brake resistance 3G3AX-RBC4001
Specification: medium capacity type. Imp