Time specification: Inverse type.
Current setting range: 50 to 160 A.
Operating voltage: 400/440 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage K8AB-PM Series PDF datasheet.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase
K8AB-PM Series
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K8AB-PM Series PDF datasheet. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Category: external supply 100mA DC10V.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with K8AB-PM Series PDF datasheet.
No output: -.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
Can enter DC0.001mInput type: PNP input type.
Event input terminal 5 points (S-TMR, HOLD, RESET) is equipped with.
External power 80mA DC12V.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Communication: RS-485; NNPN open collector (HH, H, PASS, L, LL) K8AB-PM Series PDF catalog.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
Digital rotating pulse meter with high speed measurement for 50kHz.
Action determine the color, can switch the green / Red 2 kinds of color display K8AB-PM Series PDF catalog.
Measurement of 50kHz high speed pulse.
Can rotate the encoder and a variety of ON/OFF pulse signal, up to 50kHz