LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Catalog Download
K8AB-PH1 PDF datasheet (datasheet)
Product model: K8AB-PH1
Name: Phase-sequence Phase-loss Relay
Brand: OMRON
Sort: PDF datasheet
File language: English
Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET, COMPENSATION) is equipped with.
External power supply DC12V80mA.
Linear: current; NPN open collector (OUT5, OUT4, OUT3, OUT2, OUT1).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
High speed pulse K8AB-PH1 PDF datasheet.
Measuring, increasing or decreasing pulse meter.
Action determine the color, can switch the green / Red 2 kinds of color display K8AB-PH1
The best choice of rotating encoder and all kinds of ON/OFF pulse signal at high speed,
The cumulative pulse input is 50kHz, the phase difference pulse is 25kHz, and the increase or decrease of pulse is 3Time specification: Instantaneous type.
Current setting range: 2 to 8 A K8AB-PH1 PDF datasheet.
Operating voltage: 100/110/120 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button K8AB-PH1 PDF datasheet.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Time specification: Instantaneous type.
Current setting range: 20 to 65 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation K8AB-PH1 PDF catalog.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K8AB-PH1 PDF catalog. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
Related products
OMRON
Single-phase Current Relay
K8AB-AS2 AC/DC24V
OMRON Single-phase Current Relay K8AB-AS2 AC/DC24V
Measuring current: 0.1 to 1 A AC/DC, 0.5
OMRON
Single-phase Voltage Relay
K8AB-VW2 AC100/115V
OMRON Single-phase Voltage Relay K8AB-VW2 AC100/115V
Measuring voltage: 1 to 10 V AC/DC, 3 to
OMRON
Single-phase Voltage Relay
K8AB-VW2 AC/DC24V
OMRON Single-phase Voltage Relay K8AB-VW2 AC/DC24V
Measuring voltage: 1 to 10 V AC/DC, 3 to
OMRON
Single-phase Current Relay
K8AB-AS3 AC200/230V
OMRON Single-phase Current Relay K8AB-AS3 AC200/230V
Measuring current: 10 to 100 A AC, 20 to