K3HB-VLC-FLK1ET11 AC/DC24 PDF datasheet (datasheet)
Product model: K3HB-VLC-FLK1ET11 AC/DC24
Name: Load sensor, mV instrument
Brand: OMRON
Sort: PDF datasheet
File language: English
Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET, COMPENSATION) is equipped with.
External power supply DC12V80mA.
Relay contact: OUT5; OUT31c, OUT4, OUT2, OUT1: each 1a.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
High speed pulse.
Measuring, increasing or decreasing pulse meter K3HB-VLC-FLK1ET11 AC/DC24 PDF datasheet.
Action determine the color, can switch the green / Red 2 kinds of color display K3HB-VLC-FLK1ET11 AC/DC24
The best choice of rotating encoder and all kinds of ON/OFF pulse signal at high speed,
Cumulative pulse input is 50kHz, phase difference pulse is 25kHz, increase or decrease of pulse is 30kHzInput type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET) equipped with K3HB-VLC-FLK1ET11 AC/DC24 PDF datasheet.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Relay contact: H; PASS1c, L, each 1c.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table.
Action determine the color, can switch the green / Red 2 kinds of color display K3HB-VLC-FLK1ET11 AC/DC24 PDF datasheet.
Measurement of wide range of pulse interval time.
Measuring, calculating and displaying the pulse interval between 2 points.
Pulse interval measurement range, the maximum can be measured from 10ms to 3200sRated input (See note 2.): 3-phase 3-wire mode, 3-phase 4-wire mode;
200, 220, 230, 240 VAC, 115, 127, 133, 138 VAC.
Ideal for monitoring 3-phase power supplies.
for industrial facilities and equipment.
Monitor overvoltages, undervoltages, phase sequence, and,
phase loss for three-phase 3-wire or 4-wire power supplies with,
just one Unit.
Switch setting for 3-phase 3-wire or 3-phase 4-wire power,
supply.
Two SPDT output relays, 6 A at 250 VAC (resistive load).
Output overvoltages and undervoltages using separate relays.
World-wide power specifications supported by one Unit,
(switchable).
Output status can be monitored using LED indicator. Time specification: Inverse type.
Current setting range: 20 to 65 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start off operation K3HB-VLC-FLK1ET11 AC/DC24 PDF catalog.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-VLC-FLK1ET11 AC/DC24 PDF catalog. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.