Type of input: AC voltage input.
Output type: no output.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) some models are not equipped with depth.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table K2CM-Q2LSA PDF datasheet
K2CM-Q2LSA
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
Series of DeviceNet type.
The depth (panel below) is only short size 95mm K2CM-Q2LSA PDF datasheet.
ULType: Medium-sensitivity models.
Sensed current: 100 mA/200 mA (switchable).
Type: Delayed models.
Operating time: 0.3/0.8 s (switchable).
Economical, Compact, High-performance,
DIN 48 × 48-mm Ground Fault Relay for Low,
Voltages.
Performs continuous monitoring and detection of ground faults,
in low-voltage circuits due to the deterioration of insulation in,
electrical devices K2CM-Q2LSA PDF datasheet.
Higher reliability ensured with improved resistance to high-fre,
quency noise when used for inverter loads.
Ground Fault Relays and through-type ZCTs (zero-phase current,
transformers) are mutually compatible.
The through-type ZCTs are equipped with test terminals,
allowing operation tests for Ground Fault Relays to be performed withease. Applicable circuits: Single-phase, 2-wire: 100 to 480 VAC;
Single-phase, 3-wire: 100/200 VAC; Three-phase, 3-wire: 100 to 480 VAC;
Three-phase, 4-wire: 85 to 277 VAC.
Power supply voltage (shared): 100 to 240 VAC.
Dimensions: 96 × 48 × 93 (H × W × D).
Communications: RS-485.
Protocol: CompoWay/F, 31 nodes; Modbus, 99 nodes,
(Both are supported by the same model.)
High-performance Power Monitor Suitable for On-panel Mounting and Display.
Assists Energy-saving Analysis.
Energy classification for wasted standby and stopped power.
(Classification based on external inputs is also supported.)
Power and current can be measured simultaneously.
Measurement of flow rates with a pulse conversion function.
Simple temperature measurements with Temperature Sensor included in the Unit.
High-precision Measurements.
Measurement of generated power (regenerative power),
leading reactive power, lagging reactive power, and consumed power.
Power measurements on the primary side of inverters,
which are widely used to save energy.
Automatic range switching for accurate measurement of standby and stopped power.
Energy-saving Functions.
Conversion to monetary cost. (Also used for classified standby and stopped power.)
AAlarm outputs can be selected for active power, reactive power,
regenerative power, current, voltage, or power factor K2CM-Q2LSA PDF catalog.
The Power Monitor can log measurement data and supports Modbus communications.
Installation and Settingss K2CM-Q2LSA PDF catalog.
Direct measurement of three-phase, four-wire, 400-V line voltage.
Simple measurements without voltage wiring.
Incorrect voltage wiring detection.