Specifications: Two RS-232C Ports.C200HS-CPU03-E CPU
High Performance, Small Rack Style
The C200HS-CPU01-E and C200HS-CPU03-E controllers offer some of the same basic functionality as models C200H-CPU21-E/CPU23-E.
These controllers have added capabilities ideally suited for high speed machine control,
which includes larger memory,
larger instruction set,
and increased speed CJ1W-MD231 PDF datasheet
CJ1W-MD231 Unit classifi cation: CS1 CPU Bus Unit.
Product name:Controller Link Unit.
Specifications: Communications cable,
Optical ring GI cabl;
Communications type, Data links and,
message service; Duplex support,
Yes. Unit duplexing and cable loop,
back are supported.
Max. Units mountable per CPU Unit,
Non-duplex: 8, Duplex: 11 (6 Units,
comprising 3 sets of Duplex Units,
+ 5 Non-duplex Units) CJ1W-MD231 PDF datasheet.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.65A; 26V, --.
Standards: UC1, N, L, CE.
New Controller Link Units,
Now with 4,000 Send Words.
The Controller Link is an,
FA network that can send,
and receive large amounts,
of data easily and at high speed.
The Controller Link supports data,
links that enable sharing data between,
PLCs and computers and a message service,
that enables sending and receiving,
data whenever required CJ1W-MD231 PDF datasheet.
With Wired Controller Link Units,
systems can be flexibly built by using,
Repeater Units to enable T branches,
long-distance wiring, and converting,
part of the network to optical cable. One Ethernet Option Board can be mounted in either option board slot 1 or 2.
Note: Cannot be used for the CP1L-L10.Model: CPM2C-16ET1M. Units with transistor outputs only.
1 MIL connector.
Outputs: 16 outputs.
Input type: 24 VDC.
Output type: sourcing transistor.C500-DA Special I/O Unit Analog Output C500-DA103.
Output: 4 pts.
Specification: -10~+10V.Unit type: CS1 Special I/O Units.
Product name: Isolated-type DC Input Unit.
Input points : 4 inputs.
Signal range: 4 to 20 mA, 0 to 20 mA,
1 to 5 V, 0 to 5 V, ±5 V, 0 to 10 V, ±10 V.
Conversion speed (resolution):
100ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.16A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space ccompared,
with previous systems CJ1W-MD231 PDF catalog.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CJ1W-MD231 PDF catalog.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.