LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
CJ1W-PA205R Safety Precautions ()
Product model: CJ1W-PA205R
Name: Power Supply Unit
Brand: OMRON
Sort: Safety Precautions
File language: English
Unit type: CJ1 Basic I/O Units.
Product name: DC Input Units.
Specifications: I/O points, 16 inputs;
Input voltage and current: 24 VDC, 7 mA;
Commons, 16 points, 1 common; External connection,
Removable terminal block; No. of words allocated,1 word.
Current consumption: 5V, 0.08A; 24V, -- CJ1W-PA205R Safety Precautions.
Standards: UC1, N, L, CE.
A Wide Range of Basic Input,
Units for High Speed Input and,
Different Applications CJ1W-PA205R
Receive ON/OFF signals from external,
devices into the PLC System to update,
I/O memory in the CPU Unit.
New high-speed input models CJ1W-ID212 and,
CJ1W-ID233 are now available. These units can,
help to increase system throughput. Model: CPM2A-60CDR-A. Power supply: AC power supply CJ1W-PA205R Safety Precautions.
Output type: Relay.
Inputs points: 36 points.
Outputs points: 24 points.Model : C500-LK201-EV1.
RS-232C/RS-422.Model: C200H-MD115.
No. of I/O pts: 16 inputs, 16 outputs.
Specifications: 12VDC.Name: Clamp Terminal Blocks.
Specifications: Inputs; 16 inputs ; PNP; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced CJ1W-PA205R Safety Precautions.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Unit classification: CJ1 Special I/O Units.
Product name: Process Input Units,
(Isolated type Units with Universal Inputs).
Input points: 4 inputs.
Signal range selection:
Set separately for each input.
Signal range:Fully universal
inputs: Pt100, JPt100, Pt1000, K,
J, T, L, R, S, B, 4 to 20 mA, 0 to 20 mA,
1 to 5 V, 0 to 5 V, 0 to 10 V.
Conversion speed (resolution): Conversion,
speed: 250 ms/4 inputs.
Accuracy at ambient temperature of 25°C:
Accuracy: Platinum resistance thermometer,
input: ±0.3% of PV or ±0.8°C, whichever,
is larger) ±1 digit max. Thermocouple input:
(±0.3% of PV or ±1.5°C, whichever is larger),
±1 digit max. *1 Voltage or current input:
±0.3% of F.S. ±1 digit max.
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
CCurrent consumption: 5V, 0 CJ1W-PA205R Manual. 32A; 24V, --.
Standards: UC1, L, CE.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5V).
A Unit supports four inpuut channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage) CJ1W-PA205R Manual.
All inputs are isolated.
Related products
OMRON
Position Control Units
CJ1W-NC233
OMRON Position Control Units CJ1W-NC233
Unit classification: CJ1 Special I/O Uni
OMRON
Position Control Units
CJ1W-NC414
OMRON Position Control Units  CJ1W-NC414
Unit classification: CJ1 Special I/O Uni
OMRON
Interrupt Input Units
CJ1W-INT01
OMRON Interrupt Input Units CJ1W-INT01
Unit type: CJ1 Basic I/O Units. Produ
OMRON
Output Units
CJ1W-OD201
OMRON Output Units CJ1W-OD201
Unit type: CJ1 Basic I/O Units. Produ