Applicable CPU Units: CQM1H-CPU51/61.
Connection location and number of Units: One Unit only.The Unit must be connected between the Power Supply Unit and the CPU Unit.
Dimensions: 25 × 110 × 107 mm (W × H × D).
Weight: 170 g max.Product name: N@@S1- type CPU Units with 60 I/O Points.
Specifications: Power Supply, DC24V; Inputs, 36; Outputs, 24;
Output type: Transistor (sourcing) CJ1G-CPU44H INSTRUCTIONS REFERENCE MANUAL
CJ1G-CPU44H
Program capacity: 8K steps.
memory Data capacity: 8K words.
External powersupply(24 VDC): --.
Current consumption: 5 V, 0.31A; 24 V,0.02A.
Standards: CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality CJ1G-CPU44H INSTRUCTIONS REFERENCE MANUAL.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. C500-RT SYSMAC BUS Remote I/O Master Slave Wired C500-RT001-V1.
PCF.With the optical connector 1UM: 63.2K words.
DM: 6K words.
EM: 6Kx16 banks(96K) words.
Instruction processing time (basic instructions): 0.1 µ.s min.
No CJ1G-CPU44H INSTRUCTIONS REFERENCE MANUAL. of I/O points: 1, 184 points.
Max. no.of con-necting Expansion I/O Racks: 3 Racks.
Max. no. of connecting High-density I/O Units(i.e., Group-2): Unavailable.
Max. no. of con-necting Special I/O Units: 10.
RS-232C: NO.C500-DA/3G2A5-DA Special I/O Unit Analog Output C500-DA003(3G2A5-DA003).
Output: 2 pts.
Specification: 0~+5V.Number of outputs: 32 pts.
Max. switch-ing capacity: 16 mA at 4.5 V DC to 100 mA at 26.4 V.
External connector: Connector.
Weight: 180 g max.Specification: Platinum resistance thermometer input (Pt100, JPt100),
heater burnout alarm,
manual operation,
ON/OFF or advanced PID control,
transistor (PNP) output, 2 loops.C500-ID I/O Unit DC Input 16 pts C500-ID213(3G2A5-ID213).
DC12-24V 10mA.Name: Three-tier Screw Terminal Block.
Specifications: Outputs; 16 outputs; PNP;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost ccan be reduced CJ1G-CPU44H Manual.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CJ1G-CPU44H Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.