LK Automation Limited LK Automation Limited
Information sort OMRON
Home >> Supply
OMRON CJ1W-SCU21-V1 Serial Communications Units CJ1W-SCU21-V1

Unit type: CS1 Special I/O Units.
Product name: Analog Input Unit (100 mV).
Input points : 8 inputs.
Signal range: 0 to 100 mV, ±100 mV.
Conversion speed (resolution):
200ms/8 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1 CJ1W-SCU21-V1.
Current consumption: 5V, 0.15A; 26V, 0.08A.
Standards: UC1, CE.
Prrovides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value CJ1W-SCU21-V1.
Because of this, no ladder program is required,
at the CPU Unit for scaling CJ1W-SCU21-V1.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems OMRON CJ1W-SCU21-V1.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems OMRON CJ1W-SCU21-V1.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools. Name: e-CON Connectors.
Specifications: Inputs/Outputs;
8 inputs /8 outputs; PNP;
With Short-circuit and,
Disconnected Line Detection OMRON CJ1W-SCU21-V1.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.
Unit type: CJ1 CPU Bus Units.
Product Name: Serial Communications nits.
Specifications:Communications Interface,
2 RS-232C ports;
Communications functions,
The following functions can be,
selected for each port:
Protocol macro Host Link,
NT Links (1:N mode)Serial Gateway,
No-protocol Modbus-RTU Slave.
No. of unit numbers allocated: 1.
Current consumption : 5V, 0.28A; 24V,--.
Standards: UC1, N, L, CE.
The Serial Communications Units That Enable,
High-speed Connections with External Devices.
Each Serial Communications Unit provides two,
serial communications ports: RS-232C and,
RS-422A/485, and the serial communications,
mode can be set separately for each port from,
Protocol Macro, Host Link, NT Link,
Serial Gateway, and No-protocol CJ1W-SCU21-V1.
Related supply information