LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
S8VM-03012D Connection Guide ()
Product model: S8VM-03012D
Name: Digital Controller
Brand: OMRON
Sort: Connection Guide
File language: English
I/O classification: Digital input.
Internal I/O circuit common: NPN (+ common).
I/O points: 16.
I/O connection method: Sensor connector.
Compact Remote I/O Terminals that.
Save Wiring Effort and Enable.
Long-distance Communications.
Long-distance or high-speed communications,
mode is selectable S8VM-03012D Connection Guide.
Incorporates I/O connectors making it possible to,
minimize the size S8VM-03012D
I/O connectors save wiring effort.
Flexible DIN track mounting is possible through a,
DIN track attachment.
Eight-point sensor connector models and 16-point,
MIL connector models are the same size. Conduit: JIS B 0202 G½.
Applicable cable: Cabtire cable (anticorrosive).
Inner diameter (D)of seal rubber: 9 mm.
External diameter of cable: Min, 7 S8VM-03012D Connection Guide. 5 mm; Max, 9.5 mm.
Applicable model: WL-N, WL, D4A-@N, D4B-@N, ZE, ZV, ZV2, XE, XV, XV2.
Connectors (SC Series).
Cabtire cables and flexible tubes with various diameters are used to,
connect machine tools and controllers with Limit Switches. To ensure,
the watertightness of the edges of the conduits, use an SC Connector,
that is suitable for the external diameter of cable and model of Limit Switch S8VM-03012D Connection Guide. Power ratings: 240 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC)*1.
Output voltage: 24 V.
Output current: 10 A.
Alarm output *2: Sinking.
UL Class 2 Output standards: --.
Model number(screwless terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1).
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.) Control voltage: 380/400/440 VAC.
Reset: Manual.
Model: Inverse type.
Solid--state Relay Provides Three Operating S8VM-03012D Manual.
Functions in a Compact Package.
Prevents burnouts in 3-phase induction motors due to overcurrent,
open-phase, or reverse-phase.
LEDs indicate operation of the selected operating function. S8VM-03012D Manual.
Wide setting ranges: current: 1 to 160 A; operating time: 1 to 40 s.
Protects the motor from reversing without starting it.
before using the K2CM.
Related products
OMRON
Switching Mode Power Supply
S8VM-01512CD
OMRON Switching Mode Power Supply S8VM-01512CD
Category: incidental cover type. Structu
OMRON
Switching Mode Power Supply
S8VM-01524C
OMRON Switching Mode Power Supply S8VM-01524C
Category: incidental cover type. Structu
OMRON
Switching Mode Power Supply
S8VM-15024
OMRON Switching Mode Power Supply S8VM-15024
Type: open type. Structure: ottom mount
OMRON
Switching Mode Power Supply
S8VM-01524D
OMRON Switching Mode Power Supply S8VM-01524D
Type: open type. Structure: DIN guide ra