Product model: S8JX-G05005D
Name: Digital Controller
Brand: OMRON
Sort: Connection Guide
File language: English
Power ratings: 30 W.
Input voltage: Single phase, 100 to 240 VAC, 90 to 350 VDC.
Output Voltage: 5 V.
Output current: 5 A.
Boost Current: 6 A.
Reliable and Easy Operation-Worldwide Power Supply.
Resistant in tough environments.
Easy and fast installation.
The most compact class on the market S8JX-G05005D Connection Guide.
Universal input for worldwide applications:
100 to 240 VAC (85 to 264 VAC) S8JX-G05005D
DC input can be available: 90 to 350 VDC.
Possible for 2-phase input usage.
Wide operation temperature range: –40 to 70 °C.
Power Boost function at 120%.
Safety standards:
UL508/60950-1, CSA C22.2 No. 107.1/60950-1.
EN50178, EN60950-1.
Lloyd’s standards, EN60204-1 PELV.
Safety of Power Transformers: EN61558-2-16 S8JX-G05005D Connection Guide.
ANSI/ISA 12.12.01 (excluding 480-W models).
CSA C22.2 No.213 (excluding 480-W models).
15-W,30-W, and 60-W models conform to.
UL Class 2 output Standards.
EMS: EN 61204-3.
EMI: EN 61204-3 Class B.
Three years Warranty *1. Power ratings: 100 W.
Output voltage: 12 V.
Output current: 8.5 A.
Boost current: 12.8 A.
Newly Released High-capacity 240-W Models in S8EX-series Lineup.
Rated Output of 300 W for 200 VAC S8JX-G05005D Connection Guide.
From 170 to 264 VAC.
New 240-W Models.
Lineup of models with 24-, 36-, and 48-VDC output.
voltages.
15-W, 35-W, 50-W, 100-W, and 150-W Models.
Lineup of models with from 5 to 48-VDC output.
voltages.
All Models.
Approved standards:
UL60950-1, cUR CSA C22.2 No. 60950-1, EN 50178,
and EN 60950-1.
Lineup includes open-frame models, models with.
chassis, and models with chassis and covers.
Wide-range power supply: 100 to 240 VAC.
Complies with harmonic current standard in EN.
61000-3-2 (50-W to 240-W models).
The top class in industry for compact size.
Boost current output (some models excluded). Control power supply voltage: 100/110 VAC.
Input: DC, Input voltage range, 4 to 240 mV.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL).
Detect three-phase AC current for under and/or overcur,
rent using current converter.
Availlable in 7 supply voltage configurations S8JX-G05005D Manual.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verrse current detection S8JX-G05005D Manual.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@).
Related products
OMRON
Switch Mode Power Supply
S8JX-G15005CD
OMRON Switch Mode Power Supply S8JX-G15005CD
Configuration: Covered Power Supplies.
OMRON
Switch Mode Power Supply
S8JX-G03515D
OMRON Switch Mode Power Supply S8JX-G03515D
Configuration: Covered Power Supplies.
OMRON
Switch Mode Power Supply
S8JX-G03548CD
OMRON Switch Mode Power Supply S8JX-G03548CD
Configuration: Covered Power Supplies.
OMRON
Switch Mode Power Supply
S8JX-G01548CD
OMRON Switch Mode Power Supply S8JX-G01548CD
Configuration: Covered Power Supplies.