K3HB-XAD-A-DRT1 Communications Manual ()
Product model: K3HB-XAD-A-DRT1
Name: Digital Temperature Controllers
Brand: OMRON
Sort: Communications Manual
File language: English
Collection housing: square type shell embedded ADR shell.
Purpose: high voltage non grounded system; high voltage PC (reactor) grounding system.
Digital ground directional relay K2GS-H type,
Can measure the zero phase current, zero phase voltage of the digital DGR.
And automatic test equipment can be used to test the relay conveniently K3HB-XAD-A-DRT1 Communications Manual.
Can be set for the coordination of a small number of hours to adjust the time K3HB-XAD-A-DRT1
Improve reliability by monitoring function at any time.
LED can be used to confirm the occurrence of anomalies.
The forced action of the experimental switch can be easily recognized.
Based on the DIN standard size, the depth is only small size 88.5mm. (except for terminal units)
Setting range: 10 to 100 A AC, 20 to 200 A AC K3HB-XAD-A-DRT1 Communications Manual.
Power supply voltage: 24 VAC/DC.
Ideal for Current Monitoring for.
Industrial Facilities and Equipment.
Monitor for overcurrents or undercurrents.
Use commercially available CTs (CT current on secondary,
side: 0 to 1 A or 0 to 5 A).
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately K3HB-XAD-A-DRT1 Communications Manual.
One SPDT output relay, 5 A at 250 VAC (resistive load).
Output relay can be switched between normally open and normally closed.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply. Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages or undervoltages.
Manual resetting and automatically resetting supported by one Relay.
One SPDT output relay, 6 A at 250 VAC (resistive load).
Output relay can be switched between normally open and normally closed.
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Appearance: there are F4 shell, R2 shell.
Circuit structure and open circuit mode: constant circuit contact, secondary current circuit breaker.
Rated current: AC5A.
Rated frequency: 50/60Hz (switching).
Current adjustment range: time limit elements: 3-3.5-4-4.5-5-6A, 6 shunt;
Instantaneous elements: 20-30-40-50-60A-, 6 shunt.
Action time: time limit element time to adjust the degree 0.25-0.5-1-2-3-4-5-6-7-8-9-10,
12 nominal action time to adjust the scale of 10300% over current, 10s plus or minus 5%,
700% over current, 1.52s plus or minus 7%; instantaneous elements, nominal action time 200% over current 40ms.
Control power supply: do not.
Rated consumption VA:6VA.
Contact capacity: AC12V, 60A (CT secondary current) 100 times; AC20V, 100A (CT secondary current) 3 times.
Contact: AC110V, 7.5A, COS with =0.4; (AC250V 825VA)
DC24V, 5A, L/R=7ms (maximum 50W time DC125V).
Automatic experiment: No.
Display: start display (LED), after the time display (LED).
Output display, trip (R phase and T phase) manual reset type, instant manual reset type.
Excitation surge current suppression (fuzzy inference): -.
Quality: about 1.3KG (R2 shell), about 1.8kg (F1 shell), about 3.3kg (D2 shell).
External: Mount Searl N1.5.
Static type over current relay K2CA-D type, attention to the protection of the coordination of static type OCR.
The protection coordination bbetween OCR and MCCB is simple K3HB-XAD-A-DRT1 Manual.
1 sets of three-phase protection, can save space and manpower.
Compared with the plate movement start display, through time display, make maintenance and inspection becomes simple.
The display oof the accident occurrence phase is used to facilitate the inspection after the accident K3HB-XAD-A-DRT1 Manual.
Reduce the consumption of VA, reduce the burden of converter.