K3HB-XAA-FLK3AT11 User's Manual ()
Product model: K3HB-XAA-FLK3AT11
Name: Digital Temperature Controllers
Brand: OMRON
Sort: User's Manual
File language: English
Type of input: platinum resistance / thermocouple input.
Event input terminal 4 points (TIMING, S-TIM, HOLD, RESET) is equipped with.
Communication: RS-485; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
Temperature indicator and measurement of various processes K3HB-XAA-FLK3AT11 User's Manual.
Action determine the color, can switch the green / Red 2 kinds of color display K3HB-XAA-FLK3AT11
High speed sampling of 50 /s (20ms).
0.01 degree: platinum temperature resistance body Pt100 high resolution.
Thermocouple sensor (full range) to support the resolution of 0.1.
The temperature input compensation can be easily set by 2 points Time specification: Inverse type.
Current setting range: 50 to 160 A K3HB-XAA-FLK3AT11 User's Manual.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button K3HB-XAA-FLK3AT11 User's Manual.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation, Category: external supply 100mA DC5V type.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
Communication: RS-232C; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AAC/DC24V K3HB-XAA-FLK3AT11 Manual.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified.
Action determine the color, ccan switch the green / Red 2 kinds of color display K3HB-XAA-FLK3AT11 Manual.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event transport