Function: Phase sequence and phase loss monitoring.
Rated input voltage: 3-phase, 3-wire 200 to 480 VAC.
Relay output: SPDT × 1.
Three-phase Phase-sequence Phase-loss.
Relay Using Voltage Detection Method.
Lineup includes a 17.5-mm slim, compact model.
Greater resistance to inverter noise.
Distinguishes between correct phases, phase sequence, and phase,
loss when power is turned ON K3HB-HTA-L1AT11 Communications Manual
K3HB-HTA-L1AT11
Supports phase loss detection when the motor is operating.
Output status can be monitored using LED indicator.
Ideal to prevent reverse operation of motors. Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (S-TMR, HOLD, RESET) is equipped with.
External power 80mA DC12V.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input K3HB-HTA-L1AT11 Communications Manual.
Relay contact: HH; PASS1c, H, L, LL: each 1a.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
Digital rotating pulse meter with high speed measurement for 50kHz.
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of 50kHz high speed pulse.
Rotary encoder and a variety of ON/OFF pulse signal, the most up to 50kHz high speed pulseType of input: platinum resistance / thermocouple input K3HB-HTA-L1AT11 Communications Manual.
Event input terminal 4 points (TIMING, S-TIM, HOLD, RESET) is equipped with.
Relay contact: H; PASS1c, L: each 1c.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
Temperature indicator and measurement of various processes.
Action determine the color, can switch the green / Red 2 kinds of color display.
High speed sampling of 50 /s (20ms).
0.01 degree: platinum temperature resistance body Pt100 high resolution.
Thermocouple sensor (full range) to support the resolution of 0.1.
The temperature input compensation can be easily set by 2 points.
DeviceNet type systemCategory: external supply 100mA DC10V.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
Communication: RS-485; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply volltage: AC100 ~ 240V K3HB-HTA-L1AT11 Manual.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified.
Action determine thee color, can switch the green / Red 2 kinds of color display K3HB-HTA-L1AT11 Manual.
Equipped with the sub pressure gauge for monitoring the operation trend.
External events