LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
K2CM-1L Communications Manual ()
Product model: K2CM-1L
Name: Digital Temperature Controllers
Brand: OMRON
Sort: Communications Manual
File language: English
Time specification: Inverse type.
Current setting range: 20 to 65 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage K2CM-1L Communications Manual.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase K2CM-1L
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K2CM-1L Communications Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Protect motors and other equipment from unstable,
voltages in the power supply system.
Protect motors and other equipment by detecting,
overvoltages, undervoltages, phase sequence, and,
phase loss for three-phase power supplies K2CM-1L Communications Manual.
Phase loss detection while the motor is operating.
Global power supply support. (Changed with a switch.).
Greater resistance to inverter noise.
Width of 17.5 mm to reduce space required in panels.
Push-In Plus Terminal that reduce wiring work.
The use of cage clamps enables wiring with bare stranded wires.
Double-insertion holes for crossover wiring (all terminals).
UL listed for easy shipping to North America.
Certification is pending for LR standards.
Models added with transistor outputs for superior contact reliability. Type of input: AC current input.
Output type: relay contact; 1c HH; PASS, H, L, LL: each 1a.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) some models are not equipped with depth.
The mosst suitable voltage and current signal simulation, measurement and display, identification of the panel table K2CM-1L Manual.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge forr monitoring the operation trend K2CM-1L Manual.
External event input can be applied to a variety of measurement and identification situations.
DeviceNet type system
Related products
OMRON
Over current relay
K2CA-D Series
OMRON Over current relay K2CA-D Series
Static over current relay type K2CA-D, a
OMRON
Motor Protective Relay
K2CM-2LSA
OMRON Motor Protective Relay K2CM-2LSA
Time specification: Inverse type. Curren
OMRON
Motor Protective Relay
K2CM-Q2MV
OMRON Motor Protective Relay K2CM-Q2MV
Time specification: Instantaneous type.
OMRON
Heater Element Burnout Detector
K2CU-F20A-DGS
OMRON Heater Element Burnout Detector K2CU-F20A-DGS
Control supply voltage: 110 VAC With vo