Supply voltage: 12 VDC.
Control output: Contact output, DPDT (time-limit DPDT,
or time-limit SPDT + instantaneous SPDT) Changed using a switch.
Four-mode Timer.
Multiple time ranges and operating modes let you cover a wide,
range of applications.
The time-limit DPDT output contacts can be changed to time-limit,
SPDT and instantaneous SPDT output contacts using a switch H7AN-RW6D User's Manual
H7AN-RW6D
Sequence checks are easily performed by setting an instanta,
neous output to 0.
Start signal control for the H3DK-M. Supply voltage: 24 VDC.
Time-limit contact: 4PDT (Twin contacts).
Long-time range model(0.1 min to 10 h).
Miniature Timer with Multiple Time Ranges,
and Multiple Operating Modes.
UL listed when used with a Push-In Plus Terminal Block Socket H7AN-RW6D User's Manual.
Conforms to CSA, CE Marking, LR, and CCC.
Black design with power supply terminals on top and contact output,
terminals on bottom.
Standard multiple operating modes and multiple time ranges.
Pin configuration compatible with MY Power Relay.
Minimizes stock. Operating method: Incrementing and decrementing (selectable with DIP switch).
Mounting method: Flush mounting H7AN-RW6D User's Manual.
Operation modes: N, F, C, R, K, P, Q (selectable with rotary DIP switch).
Input signal method (Count and reset inputs): Contact and transistor input, voltage (H and L).
Control output: 1-stage counters: Contact (SPDT) and transistor,
output (H and L output switchable);
2-stage counters: Contact (SPST-NO) and transistor output,
(H and L output switchable).
Set value read: Continuous mode.
Memory backup: No.
Display: Yes (10-mm high 7-segment LED, Up indicator).
Models: 4 digits; 2 stages.
A DIN 72 x 72 mm Best-selling Counter.
Easy setting with thumbwheel switches.
A draw-out construction enables maintenance without rewiring.
Models with 2-, 4-, 6-, or 8-digit displays are also available.
Total Counter models are also Available.
Complies with UL and CSA Marking. Control mode: Sunshine mode / timer mode.
Outage compensation: there.
Power supply voltage: AC100 ~ 200V.
Installation method: DIN guide rail / protocol / surface mount.
Control output: 1C * 11 circuit H7AN-RW6D Manual.
Daylight control time switch.
Rotary device with a display unit, which is always capable of reading from the front.
Accord with JIS protocol size.
There is no need to adjust the time of sunrise and sunset in support oof daylight saving time when the seasons change H7AN-RW6D Manual.
5 modes of operation. (4 kinds of Sunshine Action)
With automatic reset function, to prevent misuse.