LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
GRT1-BT1-5 OPERATION MANUAL ()
Product model: GRT1-BT1-5
Name: CompoBus/S Module
Brand: OMRON
Sort: OPERATION MANUAL
File language: English
Terminal (wire connection): Push-In Plus Terminal.
Applicable output load: AC load.
Zero cross function: No.
Rated input voltage: DC 24V.
Global standard size,
low profile slim I/O relay with width 6.2 mm,
slim I/O solid state relay.
Realized about 25% lower profile than conventional,
products, contributing to further miniaturization of the,
control panel GRT1-BT1-5 OPERATION MANUAL.
Push-In Plus terminal blocks are used to save wiring work,
in comparison with conventional screw terminals GRT1-BT1-5
(Wiring time is reduced by 60%* in comparison with,
traditional screw terminals.).
No screw loosening means maintenance-free application,
realizing high reliability.
Hand-free structure that holds an inserted flat-blade,
screwdriver to achieve easier wiring work for stranded wires GRT1-BT1-5 OPERATION MANUAL.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay or solid-state relay has a plug-in terminal.
that is difficult to bend at the time of exchange. Cable /G79-Y_C with loose wire connecting terminal.
L size: 3000mm.
Cable and loose wire cable with loose wire pressing connecting terminal,
Connector cable, MITSUBISHI motor produced PLC connection cable GRT1-BT1-5 OPERATION MANUAL. Terminal (wire connection): Screw terminal.
Applicable output load: AC load.
Zero cross function: Yes.
Rated input voltage: AC 110V.
Global standard size,
low profile slim I/O relay with width 6.2 mm,
slim I/O solid state relay.
Realized about 25% lower profile than conventional,
products, contributing to further miniaturization of the,
control panel.
Push-In Plus terminal blocks are used to save wiring work,
in comparison with conventional screw terminals.
(Wiring time is reduced by 60%* in comparison with,
traditional screw terminals.)) GRT1-BT1-5 Manual.
No screw loosening means maintenance-free application,
realizing high reliability.
Hand-free structure that holds an inserted flat-blade,
screwdriver to achieve easier wiring work for stranded wires.
Screw terminal is also stocked to meet the screw type needs GRT1-BT1-5 Manual.
Mounted relay or solid-state relay has a plug-in terminal.
that is difficult to bend at the time of exchange.
Related products
OMRON
System Units
GRT1-END
OMRON System Units GRT1-END
Name: System Units End Unit 2. Speci
OMRON
CompoNet Communications Unit
GRT1-DA2V
OMRON CompoNet Communications Unit GRT1-DA2V
Name: Slice I/O Units Analog I/O Units.
OMRON
System Units
GRT1-PD8-1
OMRON System Units GRT1-PD8-1
Name: System Units I/O Power Feed Unit.
OMRON
CompoNet Communications Unit
GRT1-TS2PK
OMRON CompoNet Communications Unit GRT1-TS2PK
Name: Slice I/O Units Temperature Input