Size: 45 × 35 mm.
Type: Plug-in.
Control method: ON/OFF operation.
Control output: Relay.
Power supply voltage: 100 to 240 VAC.
Ideal for Simple Built-in Control.
A high switching capacity of 10 A at 250 VAC enables,
direct load switching.
A sensor is provided to enable immediate application EJ1N-TC2B-CNB User's Manual.
Sockets with finger protection (PTF14A-E) or without,
finger protection (PTF14A) can be used
EJ1N-TC2B-CNB
Simple operation and settings. Even simpler with digital models. Sensor type: Diffuse-reflective.
Sensing distance: 300 mm.
Connection method: M12 connector.
Model: PNP output.
A new generation in sensing performance.
Simplicity.
Simple selection.
Simple installation.
One family for all.
All standard applications covered EJ1N-TC2B-CNB User's Manual.
A wide variety of models.
Models designed for special applications.
Non-stop detection.
High quality and reliability.
High EMC protection.
High light immunity.
Robust and waterproof housing. Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output EJ1N-TC2B-CNB User's Manual.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-232C.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) maakes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output EJ1N-TC2B-CNB Manual.
Through the infrared port can be carried out from the frront of the communication EJ1N-TC2B-CNB Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.