Appearance: M5.
Sensing distance: 3 mm.
Connecting method: M8 Pre-wired Connector Models (0.3 m).
Cable specifications: PVC (oil-resistant).
Operation mode: NC.
Wire color /pin arrangement: 1: +V, 3: 0 V, 4: Control output.
Model: NPN output.
Ultra small size, but surprisingly easy installation!
With the addition of M4, 5 EJ1G-HFUA-NFL2 User's Manual. 4-dia., 6.5-dia. size, unshielded,
pre-wired connector model, and connector model, a total of,
108 model variations are available
EJ1G-HFUA-NFL2
High-speed response frequency stably detects moving,
objects: 5 kHz max.
Four indicator lamps for easier indicator positioning.
Special mounting brackets reduce time and efforts for,
installation.
Protective Stainless-steel Spiral Tube against wire,
breakage is available (M4, M5 only) EJ1G-HFUA-NFL2 User's Manual.
Models also available with standard cables that are 5 m long,
or with robot (bending-resistant) cables. The main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling EJ1G-HFUA-NFL2 User's Manual.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. Size: 48 x 96mm.
Control output 1: voltage.
Auxiliary (alarm) output: 4.
Transfer output: -.
Event input: 2.
Communication: RS-485.
Disconnection detection: 1.
Power supply voltage: AC100 ~ 240V.
E5 - C series of new products program.
Maximum 256 segment of the program capacity,
Support for multiple applications.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
The use of high 25mm (E5AC-T), 18mm (E5AC-T) PV display (white),
Improve visibility.
Not only on the top of the body, but also on the front,
The use of communication adapter cable (sold separately) connected to the computer after,
No power connection can be set.
It can be easily set by CX-Thermo (sold separately).
High speed sampling to acchieve 50ms EJ1G-HFUA-NFL2 Manual.
With auxiliary output (4 points), event input (maximum 6 points), the transmission output,
Support a variety of applications.
Slender fuselage depth 60mm.
Easy to connect with PLC through no program communicatiion EJ1G-HFUA-NFL2 Manual.
Combined temperature control device through component communication.
Add position proportional control type, also support control valve control.