Element type: K (CA).
Terminal type: Exposed-terminal Models.
Protective tubing diameter D (mm): 15 dia.
Protective tubing length L: 75 cm.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5ER-TQ4B SETUP MANUAL.
Ideal for the thermal input devices of Temperature Controllers
E5ER-TQ4B
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: M12 (Brass); Single; Unshielded.
Sensing distance: 5 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Long E5ER-TQ4B SETUP MANUAL.
Output configuration: NPN.
Operation mode NO.
A new generation in global applications. Type: thermocouple type.
Adjustment mode: ON/OFF action or PID action.
Alarm: there.
Output: relay output.
Digital universal single display electronic temperature controller DIN 48 * 48mm self tuning (self-tuning) PID control. E3F3-D81M detection method: diffuse reflection type,
Wire lead out type,
Type: metal appearance; PNP output,
Threaded cylindrical photoelectric sensor, built-in amplifier,
Photoelectric sensor with proximity sensor appearance
High anti interference with optoelectronic -IC technologySize: M12 (Brass); Single; Unshielded E5ER-TQ4B SETUP MANUAL.
Sensing distance: 10 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Long.
Output configuration: PNP.
Operation mode NC.
A new generation in global applications. The main body: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: output (using control output).
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increaseed,
Further performance improvement E5ER-TQ4B Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV E5ER-TQ4B Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.