LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
E5EN-R3H01T-FLK-N User's Manual ()
Product model: E5EN-R3H01T-FLK-N
Name: OMRON E5EN-R3H01T-FLK-N User's Manual Digital Temperature Controller Manual
Brand: OMRON
Sort: User's Manual
File language: English
E3JK-R2S3 detection method: Regression reflection type with M.S.R. function,
Connection mode: lead wire,
Detection range: 2.5m.
Output state: when the light into the ON; light shading ON.
Output: DC no contact,
2 types of cost reductionAppearance: Standard.
Sensing method: Through beam (with slot).
Sensing distance: 5 mm (slot width) E5EN-R3H01T-FLK-N User's Manual.
Output configuration: Light-ON Dark-ON (2 outputs) E5EN-R3H01T-FLK-N
Connection method (Cable length): Pre-wired model with standard cable (1 m).
Output type: PNP.
Meeting Customer Needs with.
Ultra-compact Sensors that Mount.
with M3 Screws.
Mount using M3 or M2 screws.
Reliable sensing slot depth of 6.5 mm.
Indication of sensing window for easy confirmation of,
insertion depth E5EN-R3H01T-FLK-N User's Manual.
Bright indicator for confirmation from many directions.
Both light-ON and dark-ON outputs provided.
All models available with either standard cable or,
flexible robot cable.
Load short-circuit protection circuit provided. Element type: J (IC).
Terminal type: Exposed-terminal Models.
Protective tubing diameter D (mm): 4.8 dia.
Protective tubing length L: 35 cm.
A Wide Variety of High-precision E5EN-R3H01T-FLK-N User's Manual.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Appearance: Unshielded, M30.
Sensing distance: 15 mm.
Output configuration: AC 2-wire.
Model: Operation mode, NO.
General-purpose Threaded.
Capacitive Sensor.
Product lineup with M12, M18, and M30 models.
Fixed sensing distance requires no sensitivity adjustment. Size: 48 * 48mm, terminal type.
Type: control output 2 point type (power AC/DC24V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: -.
Event entry point: 2.
Transfer output: -.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the tthermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV E5EN-R3H01T-FLK-N Manual.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can performm flexible contact output E5EN-R3H01T-FLK-N Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
Related products