Type: Device Net.
The DeviceNet Communication Unit That.
Simplifies Managing Sensor Settings.
ON/OFF signals and incident light levels can be sent to the host,
PLC without any need for programming (DeviceNet communications,
slave functionality).
Threshold values and function settings can be read, written,
or taught (using the Message Communications function) E5EN-Q3PT-N User's Manual.
Simply connect the communication cables and slide the Amplifiers,
from the side for wire-saving
E5EN-Q3PT-N
Up to 16 Sensor Amplifiers can be connected. Appearance: Unshielded.
Sensing surface: Top.
Sensing distance: 1.6 mm.
Model: Operation mode, NC.
Advanced Performance and Wide.
Range of Selections in a Super.
compact Size.
Only 5 E5EN-Q3PT-N User's Manual. 5 × 5.5 mm with a built-in Amplifier.
Maximum sensing distance: 2.5 mm. Stable detection even with,
workpiece fluctuations.
Response frequency: 1 kHz.
Low current consumption. Temperature range: 60 to 110.
Digital thermometer for replacing alcohol thermometer.
With the aid of microcomputer, high precision can be realized (with 0.1 degree C as the unit).
Built in battery, no power supply connection E5EN-Q3PT-N User's Manual.
Large LCD (character height 12mm) digital display. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 8 dia. . .
Protective tubing length L: 35cm.
Lead wire type: Heat resistive.
Lead wire length M : 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Detection mode: diffuse reflection type.
Connection mode: lead type (2 m)
Detection distance: infrared 300mmm.
Output mode: NPN output. Size: 48 x 48mm.
Body: terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
SSR fault detection function for heater with broken line: detection function for single phase heater.
Event entry point: 2.
Transfer output: -.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensorss E5EN-Q3PT-N MANUAL.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to eexecute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault