E5EN-Q3HMT-500 User's Manual ()
Product model: E5EN-Q3HMT-500
Name: Temperature Controller
Brand: OMRON
Sort: User's Manual
File language: English
Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard.
No. of auxiliary outputs: --.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, E5GN-QTC;
Resistance thermometer input, E5GN-QP E5EN-Q3HMT-500 User's Manual.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance E5EN-Q3HMT-500 Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks E5EN-Q3HMT-500 User's Manual.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors E5EN-Q3HMT-500 User's Manual.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Size: M12 (Brass); Double; Unshielded.
Sensing distance: 8 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Short.
Output configuration: PNP.
Operation mode NC.
A new generation in global applications. Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard.
Auxiliary output points: -.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Fuurther performance improvement E5EN-Q3HMT-500 MANUAL.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV E5EN-Q3HMT-500 MANUAL.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Related products
OMRON
Foundation type temperature controller
E5EN-Q3HHBBL-N
OMRON Foundation type temperature controller E5EN-Q3HHBBL-N
Size: 48 x 96mm. Ontology: terminal type
OMRON
Foundation type temperature controller
E5EN-Q3HHT-N
OMRON Foundation type temperature controller E5EN-Q3HHT-N
Size: 48 x 96mm. Ontology: terminal type
OMRON
Foundation type temperature controller
E5EN-Q3HBL-N
OMRON Foundation type temperature controller E5EN-Q3HBL-N
Size: 48 x 96mm. Ontology: terminal type
OMRON
Foundation type temperature controller
E5EN-Q3HTD-N
OMRON Foundation type temperature controller E5EN-Q3HTD-N
Size: 48 x 96mm. Ontology: terminal type