Sensing method: BGS reflective (fixed distance).
Connection method: Connector (M8, 4 pins).
Sensing distance: 10 to 200 mm.
Model: NPN output .
Stainless Steel Housing Ideal for Food Industry PAT Pending.
Strong resistance against detergents, disinfectants, and jet liquid flow.
Product lineup includes BGS Reflective Models and Through-beam,
Models with built-in slits E5EN-Q3H01T-FLKAC100-240 User's Manual
E5EN-Q3H01T-FLKAC100-240
Certified by Ecolab Europe. Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 4.8 dia.
Protective tubing length L: 50 cm.
Lead wire type: Heat resistive.
Lead wire length M: 8m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5EN-Q3H01T-FLKAC100-240 User's Manual.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. E32-D11L type: special beam type; long range / high function,
Specialty: M6 screw,
Bending radius (mm): R25 E5EN-Q3H01T-FLKAC100-240 User's Manual.
Standard test object (minimum test object) (mm) 1: (0.005),
Fiber element for meeting diversified needsSize: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: high life relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/SSTOP, alarm), interactive display PV/SV E5EN-Q3H01T-FLKAC100-240 Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E5EN-Q3H01T-FLKAC100-240 Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.