Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 4.8 dia.
Protective tubing length L: 20cm.
Lead wire type: Standard.
Lead wire length M : 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5EN-HAA2HH02BF-FLK Basic Type.
Ideal for the thermal input devices of Temperature Controllers
E5EN-HAA2HH02BF-FLK
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 48 * 48mm, terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black E5EN-HAA2HH02BF-FLK Basic Type.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase heater detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved E5EN-HAA2HH02BF-FLK Basic Type.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Appearance: L-shaped.
Sensing method: Throughbeam type(with slot).
Connecting method: Connector(4 poles).
Sensing distance: 5 mm (slot width).
Output configuration: Dark-ON/Light-ON (selectable).
Indicator mode: No incident light.
Model: PNP output.
Global Standard Slot-type.
photomicrosensors with 50- to,
100-mA direct switching capacity.
Series includes models that enable switching between,
dark-ON and light-ON operation E5EN-HAA2HH02BF-FLK Manual.
Response frequency as high as 1 kHz.
Easy operation monitoring with bright light indicator.
Wide operating voltage range: 5 to 24 VDC.
Models in which the light indicator turns ON for ddark-ON,
operation are also available E5EN-HAA2HH02BF-FLK Manual.
A wide range of variations in eight different shapes.
Flexible robot cable is provided as a standard feature.