LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
E5EN-HAA2HBMD-500 Basic Type (Basic Type)
Product model: E5EN-HAA2HBMD-500
Name: OMRON E5EN-HAA2HBMD-500 Manual E5EN-HAA2HBMD-500 Basic Type Basic Type
Brand: OMRON
Sort: Basic Type Basic Type
File language: English
E32-T81R-S type: environment resistant; heat resistant,
Specialty: heat resistant: 200,
Shape / detection distance (mm): 360; 280; 180 (70),
Bending radius (mm): R10.
Standard test object (minimum test object) (mm) 1: 1 (0.005),
Fiber element for meeting diversified needsSize: 48 x 24mm.
Control output 1: voltage output (SSR driver) E5EN-HAA2HBMD-500 Basic Type.
Control output 2:--.
Auxiliary output: - E5EN-HAA2HBMD-500
Power supply voltage: AC100 ~ 240V.
Terminal type: screw terminal table type (with terminal cover).
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: -.
Event input: -.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance E5EN-HAA2HBMD-500 Basic Type.
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc..
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance performance.
The connection method can be selected from a screw terminal and a PUSH-IN fastening terminal E5EN-HAA2HBMD-500 Basic Type.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication conversion Village (sold separately) connected to the computer after,
No power connection can be set.
It can be easily set by CS-Thermo (sold separately). Size: 96 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-422.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E5EN-HAA2HBMD-500 Manual.
Through the infrared port can be carried out from the frront of the communication E5EN-HAA2HBMD-500 Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
Related products