Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 1 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use E5EN-C3BL-N User's Manual
E5EN-C3BL-N
Event input points: -.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV E5EN-C3BL-N User's Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc E5EN-C3BL-N User's Manual. , can be a key operation. Setting: simulation settings.
Indication mode: no indication.
Adjustment mode: proportional action (P).
Output: relay.
Input: thermocouple K.
The size of the DIN48 to achieve the simulation set, low cost.
The most small and realize the low cost of.
Proportional (P) action in the regulation mode.
And the reset function is added.
Through the installation of the adapter can be continuously close.
The installation of DIN guide rail and panel mounting can be carried out by means of insertion. Size: 48 x 48mm.
Control output 1: voltage output (SSR driver).
Control output 2:--.
Auxiliary output: 2 independent points.
Power supply voltage: AC/DC24V.
Terminal type: screw terminal table type.
Input category: full range multi input.
Heater disconnection, SSR fault detection function: 1 points.
Communication: -.
Event input: 2 points.
Remote SP input: -.
Transfer output: -.
Using large font PV display (white), improve visibility.
Selection, operation and setting.
Functional performance of input and output points.
Support for more extensive range of applications.
Using high PV 15.2mm display (white), improve visibility.
High speed sampling to achieve 50ms.
With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
Remote SP input function, support for a varietty of applications E5EN-C3BL-N Manual.
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer.
After that, no power supply connection can be set.
It can be easily set by CX-Thermmo (sold separately) E5EN-C3BL-N Manual.
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication.