Sensing method: Convergent reflective.
Connection method: Pre-wired (2 m).
Sensing distance : 20 to 35 mm .
function Timer: With .
Model: PNP output.
Reliable Detection Unaffected by PCB.
Holes or Notches.
High-limit E3S-LS3@ is suitable for incorporation in devices.
Wide-range E3S-LS3@W is ideal for detecting tall components,
mounted on boards E5EC-RR4ASM-008 User's Manual.
Timer function models available
E5EC-RR4ASM-008 Size: 1/4 DIN 96 × 96 × 78 (W × H × D).
Power supply voltage: 100 to 240 VAC.
Input type: Thermocouple or Resistance thermometer.
Alarm output: 3.
Control output: Current output.
Functions: Heater burnout, No; Mounting option units, No.
Previous model: E5AZ-C3 E5AZ-A3 + E53-AZC.
These Best-selling General,
purpose Temperature Controllers,
Are Now Even Better E5EC-RR4ASM-008 User's Manual.
Controllers now available with analog inputs.
Faster sampling at 250 ms.
Transfer output provided for easy output to recorders.
Models available with a loop break alarm (LBA) and,
heater short alarm (HS alarm).
Manual output provided.
Easy setting with 11-segment displays.
New protocol called Modbus is installed in the,
models with communications E5EC-RR4ASM-008 User's Manual.
USB-Serial conversion cable is available.
Note: Refer to Precautions on page 33. Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, E5GN-Q1TC;
Resistance thermometer input, E5GN-Q1P.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Teemperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5EC-RR4ASM-008 Manual.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E5EC-RR4ASM-008 Manual.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.