E5EC-CQ2ASM-008 User's Manual ()
Product model: E5EC-CQ2ASM-008
Name: Digital Temperature Controllers E5EC-CQ2ASM-008 Manual OMRON E5EC-CQ2ASM-008 User's Manual
Brand: OMRON
Sort: User's Manual
File language: English
Size: 96 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function E5EC-CQ2ASM-008 User's Manual.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input E5EC-CQ2ASM-008
Communication: RS-232C.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms E5EC-CQ2ASM-008 User's Manual.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E5EC-CQ2ASM-008 User's Manual.
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Size: 48 x 96mm.
Type: thermocouple type.
Adjustment mode: ON/OFF action or PID action.
Alarm: single alarm.
Output: voltage output (for driving SSR).
Temperature controller with single alarm output.
SV and PV can be displayed at the same time.
Multiple temperature range allows setting the optimum temperature range.
The protection function can prevent the error in operation. The main body: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver)
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Furrther performance improvement E5EC-CQ2ASM-008 Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV E5EC-CQ2ASM-008 Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Related products
OMRON
Digital temperature controller
E5EC-CQ4ASM-012
OMRON Digital temperature controller E5EC-CQ4ASM-012
Size: 48 x 96mm. Control output 1: line
OMRON
Digital temperature controller
E5EC-CQ2DSM-000
OMRON Digital temperature controller E5EC-CQ2DSM-000
Size: 48 x 96mm. Control output 1: line
OMRON
Digital temperature controller
E5AC-QR2ASM-008
OMRON Digital temperature controller E5AC-QR2ASM-008
Size: 96 x 96mm. Control output 1: volt
OMRON
Digital temperature controller
E5EC-QQ2ASM-008
OMRON Digital temperature controller E5EC-QQ2ASM-008
Size: 48 x 96mm. Control output 1: volt