Model: Shielded, M12.
Sensing distance: 2 mm.
Output configuration: DC 3-wire, NPN.
Model: Operation mode, NC.
Proximity Sensor with Resin Case,
with Superb Water Resistance.
IP68 protection.
Mutual interference prevention with models with different,
frequencies is also available. Size: 48 x 96mm E5CN-RMTD-500 User's Manual.
Control output 1: double relay (proportional valve).
Auxiliary (alarm) output: 4
E5CN-RMTD-500
Transfer output: have.
Event input: 4.
Communication: RS-485.
Break detection: -.
Power supply voltage: AC100 ~ 240V.
E5 - C series of new products program.
Maximum 256 segment of the program capacity,
Support for multiple applications.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
The use of high 25mm (E5AC-T), 18mm (E5AC-T) PV display (white),
Improve visibility E5CN-RMTD-500 User's Manual.
Not only on the top of the body, but also on the front,
The use of communication adapter cable (sold separately) connected to the computer after,
No power connection can be set.
It can be easily set by CX-Thermo (sold separately).
High speed sampling to achieve 50ms.
With auxiliary output (4 points), event input (maximum 6 points), the transmission output,
Support a variety of applications E5CN-RMTD-500 User's Manual.
Slender fuselage depth 60mm.
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication.
Add position proportional control type, also support control valve control. Temperature range: -30.0 ~ 20.
Positive / reverse action: positive action (cooling).
Adjustment mode: OFF, ON action.
With the aid of microcomputer, the temperature control can be realized with high precision (0.1 degrees C).
Combined use of control equipment, adjustable sensitivity.
Attached to facilitate the energy saving operation of the set value conversion function, as well as ease of operation to stop the control function. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 1 dia.
Protective tubing length L: 20 cm.
Lead wire type: Standard.
Lead wire length M : 1m.
A Wide Variety of High-precision.
Temperaturre Sensors E5CN-RMTD-500 Manual.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Teemperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E5CN-RMTD-500 Manual.