LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
E5CN-Q2HH03TD-FLK USER'S MANUAL ()
Product model: E5CN-Q2HH03TD-FLK
Name: Digital Temperature Controller
Brand: OMRON
Sort: USER'S MANUAL
File language: English
Power supply voltage: 5 to 24 VDC.
Output configuration: Open-collector output (NPN).
Resolution (pulses/rotation): 10, 20, 30, 40, 50, 60, 100,
200, 300, 360, 400, 500, 600; 720, 800, 1,000, 1,024,
1,200, 1,500, 1,800, 2,000.
General-purpose Encoder with.
External Diameter of 50 mm.
Incremental model E5CN-Q2HH03TD-FLK USER'S MANUAL.
External diameter of 50 mm.
Resolution of up to 2,000 ppr E5CN-Q2HH03TD-FLK
IP64 (improved oil-proof construction with sealed bearings).
Side or back connections are possible. Pre-wired Models with cable,
connected at an angle. Control output: voltage output (SSR driver).
Auxiliary output: 2 points.
Heating wire breakage, SSR fault detection function: single phase heater detection function.
Event input: 1 points E5CN-Q2HH03TD-FLK USER'S MANUAL.
Communication: -.
Terminal shape: screw terminal table type (main unit + terminal unit).
Power supply voltage: AC100 ~ 240V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type.
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body E5CN-Q2HH03TD-FLK USER'S MANUAL.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating.
Easy to connect with PLC through no program communication.
The use of communication adapter cable (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately).
With auxiliary output (maximum 2 points), event input (maximum 1 points), the basic function is complete.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8.5mm). Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Furthher performance improvement E5CN-Q2HH03TD-FLK Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV E5CN-Q2HH03TD-FLK Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Related products