LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
E5CN-HR2MD-500 User's Manual ()
Product model: E5CN-HR2MD-500
Name: Temperature Controller
Brand: OMRON
Sort: User's Manual
File language: English
Lead wire length: 1m.
Element type: J (IC).
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E5CN-HR2MD-500 User's Manual E5CN-HR2MD-500 The main body: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: silver.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points E5CN-HR2MD-500 User's Manual.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement E5CN-HR2MD-500 User's Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. A New High-performance Controller: High Resolution, High Speed,
and High Input Accuracy.
Logic Operations and Preventive.
Maintenance Function.
High-resolution display with 5 digits/0.01°C display in a compact,
Controller (48 x 48 mm).
High-speed sampling cycle of 60 ms.
High Accuracy,
Thermocouple/Pt input: ±0.1% of PV,
Analog input: ±0.1% FS,
Universal inputs on all models (thermocouple, PT, or analog,
input) to handle various sensors with one Controller.
A PV/SV-status display function can be seet to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5CN-HR2MD-500 Manual.
Flexible contact outputs with logic operations (AND, OR, and,
delays) set froom the Support Software (CX-Thermo Ver E5CN-HR2MD-500 Manual. 4.0),
Preventive maintenance for relays in the Temperature.
Controller using a Control Output ON/OFF Counter.