Element type: K (CA).
Terminal type: Exposed-terminal Models.
Protective tubing diameter D (mm): 4.8 dia.
Protective tubing length L: 75 cm.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5CN-HQ2HBD USER'S MANUAL.
Ideal for the thermal input devices of Temperature Controllers
E5CN-HQ2HBD
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 96 x 96mm.
Type: thermocouple type.
Adjustment mode: ON/OFF action or PID action.
Alarm: single alarm.
Output: relay output E5CN-HQ2HBD USER'S MANUAL.
Temperature controller with single alarm output.
SV and PV can be displayed at the same time.
Multiple temperature range allows setting the optimum temperature range.
The protection function can prevent the error in operation. Appearance: Flat Unshielded.
Sensing distance: 10 mm[4 to 10 mm *].
Output configuration: DC 3-wire NPN.
Model/Operation mode: NC.
Flat Capacitive Sensor with a.
Thickness of Only 10 mm E5CN-HQ2HBD USER'S MANUAL.
Flat Sensor with excellent space efficiency.
(Model with built-in Amplifier is only 10 mm thick.)
Direct mounting onto a metallic surface is possible. Ultra small rotary encoder (diameter 20) - absolute.
Machine built in super small.
The diameter of 20mm size, resolution 256 (8bit).
Axle and hollow shaft type.
Power supply voltage: DC5V.
Output form: NPN open collector output.
Resolution (segmentation):256.
Axis shape: shaft extension. Size: 1/16 DIN.
Case color: Black.
Power supply voltage: 24 VAC/VDC.
Input type: Thermocouple or resistance thermometer.
Auxiliary outputs: 2.
Control output 1: Voltage output (for driving SSR).
New 48 x 48-mm Basic Temperature.
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0 E5CN-HQ2HBD Manual. 5%),
New E5CN-U Models (Plug-in Models) with analog inputs and,
current outputs.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
mannual, RUN/STOP, and alarms) and the PV or SV E5CN-HQ2HBD Manual.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.