Sensing method: Through-beam type (with slot).
Sensing distance: 3.6 mm (slot width).
Output type: NPN output.
Output configuration: Light-ON.
Photomicrosensor with light,
modulation for reduced external,
light interference and a,
connector for easy maintenance.
Built-in connectors.
Select from four easy-to-use shapes for efficient space,
utilization E5CN-C2TU User's Manual.
Connectors with locks for safety against vibration
E5CN-C2TU
Convenient mounting method using M3 screws.
Wide operating voltage range: 5 to 24 VDC. Ontology: terminal type, analog input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: relay output.
Control output 2: voltage output (SSR driver)
Control mode: standard or heating cooling E5CN-C2TU User's Manual.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement E5CN-C2TU User's Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. Appearance: Unshielded.
Sensing surface: Top.
Sensing distance: 2.5 mm.
Model: Operation mode, NC.
Advanced Performance and Wide.
Range of Selections in a Super.
compact Size.
Only 5.5 × 5.5 mm with a built-in Amplifier.
Maximum sensing distance: 2.5 mm. Stable detection even with,
workpiece fluctuations.
Response frequency: 1 kHz.
Low current consumption. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 3.2 dia.
Protective tubing length L: 15cm.
Lead wire type: Heat resistive.
Lead wire length M : 2m.
A Wide Variety of High-precision.
Temperrature Sensors E5CN-C2TU MANUAL.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Teemperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E5CN-C2TU MANUAL.