Detection mode: diffuse reflection type.
Connection mode: lead type (2 m)
Detection range: red light 1mmmm.
Output mode: PNP output. Detection methods: on the radio type (projector + optical device).
Connection mode: lead type (2 m)
Detection range: red light 20m.
Output mode: NPN output.
Optical projector: 2M E3Z-FTN11-L E5CC-TRX3DSM-060 lnstruction Manual.
Optical device: 2M E3Z-FTN11-D. Size: 48 x 96mm
E5CC-TRX3DSM-060
Ontology: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use E5CC-TRX3DSM-060 lnstruction Manual.
Event input points: -.
Transfer output: output (using control output).
Communication: RS-485.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV E5CC-TRX3DSM-060 lnstruction Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. E3JM-DS70S4T detection method: diffuse reflection type,
Connection: terminal plate,
Detection range: 700mm.
Output status: ON into the light; light shading ON; switch conversion type.
Output: DC no contact. Function: timer,
2 types of cost reductionSize: 96 x 96mm.
Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 4.
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manuaal, RUN/STOP, alarm), interactive display PV/SV E5CC-TRX3DSM-060 Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E5CC-TRX3DSM-060 Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.